Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Journal of Sun Yat-sen University(Medical Sciences) ; (6): 622-628, 2019.
Article in Chinese | WPRIM | ID: wpr-817755

ABSTRACT

@#【Objective】To explore the image evaluation value of multi-model CT in the treatment of acute ischemic stroke with Solitaire stent embolectomy. 【Methods】 A total of 62 patients diagnosed with acute ischemic stroke from January 2015 to June 2016 in Guangdong Second Provincial General Hospital were included in this study. Multi- model CT inspection,including CT scan(NCCT),CT angiography(CTA)and CT perfusion imaging(CTP),was performed in all patients within 3~8 h. The improved vascular TICI classification standard(mTICI)was used to assess vascular embolization,and we evaluated the responsible vessels and blood perfusion state by CTA and CTP blood vessels ,to determine the feasibility of embolectomy with Solitaire stent preliminarily. The patients underwent multi-mode CT examination 24 h after stent embolization to evaluate the responsible vessels. NIHSS was used to assess the neurological function at admission and 72 h after stent embolization.【Results】A total of 34 patients with indication of stent thrombus removal were selected by multi-mode CT examination from 62 patients. Re-examination of multi-mode CT after stent thrombus removal showed that 30 of the 34 cases(30/34,the successful rate was 88.2%)gained success in vascular recanalization. Before the stent thrombus removal of the 34 patients,CTP imaging showed ischemic penumbra(IP),and there was significant decrease in cerebral blood flow(CBF)and slight decrease in cerebral blood volume(CBV),significantly prolonged peak time (TTP) and mean transit time (MTT) compared with the contralateral image area. The difference is statistically significant(P < 0.01). After the stent thrombus removal,the relative cerebral blood flow(rCBF)and relative cerebral blood volume(rCBV)were elevated,the relative peak time(rTTP)and relative mean transit time(rMTT)were shortened. The difference is statistically significant(P < 0.01). Compared with admission,there is significant statistical difference in the NIHSS score of patients 72 h after operation(P < 0.01).【Conclusion】Multi-model CT has guiding effect and important evaluation value in the treatment of acute ischemic stroke patients with Solitaire stent thrombolysis.

2.
Chinese Journal of Contemporary Pediatrics ; (12): 800-805, 2015.
Article in Chinese | WPRIM | ID: wpr-279049

ABSTRACT

<p><b>OBJECTIVE</b>To study the diagnostic values of fractional exhaled nitric oxide (FeNO) for typical bronchial asthma and cough variant asthma in children, and to explore whether FeNO can be applied to differentiate typical bronchial asthma from cough variant asthma in children.</p><p><b>METHODS</b>A total of 150 children who were newly diagnosed with typical bronchial asthma between June 2012 and June 2014, as well as 120 children who were newly diagnosed with cough variant asthma during the same period, were selected as subjects. FeNO measurement, spirometry, and methacholine provocation test were performed for both groups. Meanwhile, 150 healthy children were selected as the control group, and their FeNO was measured. The diagnostic values of FeNO for typical bronchial asthma and cough variant asthma were analyzed using the receiver operating characteristic curve.</p><p><b>RESULTS</b>The FeNO values in the typical bronchial asthma and cough variant asthma groups were significantly higher than in the control group (P<0.01), and the FeNO value in the typical bronchial asthma group was significantly higher than in the cough variant asthma group (P<0.01). FEV1/FVC%, FEV1%pred, and PD20 were significantly lower in the typical bronchial asthma group than in the cough variant asthma group (P<0.01). The optimal cut-off value of FeNO was 19.5 ppb for the diagnosis of typical bronchial asthma, with a sensitivity of 83.3% and a specificity of 86.7%; the optimal cut-off value of FeNO was 15.5 ppb for the diagnosis of cough variant asthma, with a sensitivity of 67.5% and a specificity of 78.0%; the optimal cut-off value of FeNO was 28.5 ppb for the differentiation between typical bronchial asthma and cough variant asthma, with a sensitivity of 60.7% and a specificity of 82.5%.</p><p><b>CONCLUSIONS</b>Measurenment of FeNO may be useful in the diagnosis and differential diagnosis of typical bronchial asthma and cough variant asthma.</p>


Subject(s)
Child , Female , Humans , Male , Asthma , Diagnosis , Breath Tests , Cough , Diagnosis , Forced Expiratory Volume , Nitric Oxide , ROC Curve , Vital Capacity
SELECTION OF CITATIONS
SEARCH DETAIL